LockSpray Exact Mass Ionization Source

LockSpray Exact Mass Ionization Source

Make exact mass measurements easy

Make exact mass measurements easy

The LockSpray dual electrospray ion source optimizes the co-introduction of analyte and lock mass compound directly into the ion source, providing authenticated exact mass measurement in MS and MS/MS modes to within 5 ppm RMS mass accuracy (3 ppm for Xevo QTof MS and 1 ppm for Xevo G2 Tof series, Xevo G2 QTof series, and SYNAPT G2 series).

The increased specificity associated with exact mass measurement provides you with improved efficacy in compound or fragment identification in metabolite profiling and proteomics applications.

Traditionally, to obtain valid exact mass measurement, an internal reference or “lock mass” was used to correct for changes in environment or experimental conditions over the course of the analysis. This was achieved by “teeing in” a suitable reference compound to the main analyte flow. However, this approach often suffered from ionization suppression, potential mass interferences, and solvent gradient effects.

The LockSpray source design overcomes these limitations.

LockSpray Exact Mass Ionization Source

Overview



LockSpray source operation

With the LockSpray source, the conventional electrospray inlet is replaced by a new outer source housing containing an additional pneumatically assisted electrospray probe for the introduction of the lock mass reference.

An oscillating baffle driven by a programmable stepper motor samples the two electrospray streams separately. The reference spray is sampled at pre-defined intervals so that the acquisition duty cycle favors the analyte liquid stream.

The sampling baffle position is monitored in real time to allow the two liquid inlets to be indexed and the reference and sample data stored in separate files. The LockSpray source design eliminates cross-talk between the analyte and reference channels, ensuring the integrity of the exact mass data.


Instrument compatibility

The LockSpray Interface/Ionization Source is available for the following MS instruments:

  • Xevo G2 QTof, Xevo G2-S QTof, Xevo G2-XS QTof
  • Xevo G2 Tof, Xevo G2-S Tof, Xevo G2-XS Tof
  • (MALDI) SYNAPT G2 MS/HDMS, (MALDI) SYNAPT G2-S MS/HDMS, (MALDI) SYNAPT G2-Si MS/HDMS

Equipment and installation

The LockSpray interface/source enclosure includes an electrospray source inlet assembly with additional low flow (~10 µL/min) reference supply probe and indexed stepper motor control of the spray selection rotor. The interface is operated in conjunction with the standard co-axial electrospray probe. A separate ESI probe is included with Xevo QTof, Xevo G2 Tof/QTof series, and SYNAPT G2 series LockSpray source enclosures.

The exact mass source assembly requires installation and operation training by a Waters Field Service Engineer.



Resources

Documents

Documents


Support

Support


Related

The only way to access multiple dimensions of resolution for the highest levels of separation, specificity and confidence in analysis. A uniquely powerful and versatile platform for imaging, life science research and chemical material characterization.

SYNAPT G2-Si MS provides the most uncompromising High Resolution UPLC-MS/MS performance, with the greatest versatility and upgrade option to access 3 dimensions of resolution for the ultimate in discovery power.

Routine high resolution MALDI MS/MS performance and unparalleled analytical versatility for a wide range of applications - from imaging and life science research to characterization of chemical materials.

The NanoLockSpray™ dual electrospray ion source accessory with optimized co-introduction of analyte and lock mass compounds provides authenticated exact mass measurement in NanoFlow™ LC-MS and LC-MS/MS modes of operation.

A benchtop QTof mass spectrometer incorporating the XS Collision Cell for enhanced sensitivity and selectivity, resulting in the highest quality, most comprehensive qualitative information together with the ultimate in quantitative performance.
Back To Top Back To Top