XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002984
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    130 Å

  • Format

    Prep Guard Cartridge

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    1 pk

SKU: 186003999
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003999
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    OBD Prep Column

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    50 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186008214
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008214
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    OBD Prep Column

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    10 mm

  • Length

    250 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186008170
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008170
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    OBD Prep Column

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    10 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 176002562
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 176002562
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    XP Column

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    30 mm

  • Carbon Load

    17 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    3 pk

SKU: 186006059
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186006059
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    XP Column

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003073
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003073
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    130 Å

  • Format

    Sentry Guard Cartridge

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    20 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    2 pk

SKU: 186003005
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003005
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003069
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003069
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Pore Size

    130 Å

  • Format

    Sentry Guard Cartridge

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    20 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    2 pk

SKU: 186003157
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003157
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Intelligent Speed (IS) Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    30 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003002
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003002
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003161
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003161
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    250 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003008
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003008
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

Prep Guard Cartridge 30 mm x 10 mm
SKU: 186006898
Category: Columns
30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.
Part Number: 186006898
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    130 Å

  • Format

    Prep Guard Cartridge

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    30 mm

  • Length

    10 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    1 pk

SKU: 186003153
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003153
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Intelligent Speed (IS) Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    30 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003040
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003040
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186008168
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008168
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    OBD Prep Column

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    10 mm

  • Length

    50 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186003037
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003037
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003003
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003003
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003155
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003155
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Intelligent Speed (IS) Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    30 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003041
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003041
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186003004
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003004
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: 186007802
Category: Columns
XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 3.5 µm sorbent particles.
Part Number: 186007802
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    3 pk

SKU: 186007804
Category: Columns
XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 3.5 µm sorbent particles.
Part Number: 186007804
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    3 pk