Xevo TQ-XS Triple Quadrupole Mass Spectrometer
Superior performance in your routine quantitative analyses
Expanding your analytical capabilities with the next step in detection, the Xevo TQ-XS offers superior performance for your routine quantitative workflows. With solutions for today’s needs and technologies to overcome tomorrow’s challenges, explore what the adaptable, flexible, and proven Xevo TQ-XS Tandem Quadrupole Mass Spectrometer coupled with ACQUITY UPLC can afford your laboratory’s productivity and capabilities.
Would you like to maximize your lab budget?
Optimize your capital resources and easily access customized support and the new technology your lab needs with leasing, technology refresh, and rental solutions from Waters Capital. Explore Financing Solutions →
Specifications
API sources and ionization modes |
High performance ZSpray™ dual-orthogonal API sources: 1) Multi-mode source – tool free ESI/APCI/ESCi™* (standard) NB – Dedicated APCI requires an additional probe (optional) 2) UniSpray™ ion source (optional) 3) Tool-free APCI probe (optional) 4) nanoFlow™ ESI source* (optional) 5) ASAP* (optional) 6) APGC ion source* (optional) 7) ionKey™ source* (optional) Optimized gas flow dynamics for efficient ESI desolvation Tool-free source exchange Vacuum isolation valve Tool-free access to user serviceable elements Plug-and-play probes De-clustering cone gas Software control of gas flows and heating elements |
UniSpray ion source option |
UniSpray is an ionization technique designed to broaden the scope of compounds which can be analyzed in a single run, including those which typically optimize in ESI, APCI or APPI. Enhanced ionization efficiency and desolvation allow the potential to combine several methodologies into one, or simply enable the operator to keep the same source for multiple methods, requiring less time performing set-up and routine maintenance, and more time delivering results |
Ion source transfer optics |
StepWave XS ion transfer optics delivering class leading UPLC™-MS/MS sensitivity. The unique off-axis design and segmented quadrupole second stage dramatically increases the efficiency of ion transfer from the ion source to the quadrupole MS analyzer at the same time as actively eliminating undesirable neutral contaminant |
Mass analyzer |
Two high-resolution, high-stability quadrupole analyzers (MS1/MS2), plus pre-filters to maximize resolution and transmission while preventing contamination of the main analyzers |
Collision cell |
T-Wave™ enabled for optimal MS/MS performance at high data acquisition rates; Software programmable gas control |
Detector |
Low-noise, off-axis, long-life photomultiplier XDR detector |
Vacuum system |
Three air-cooled turbomolecular vacuum pumps One vacuum backing pump |
Dimensions |
Width: 61.0 cm (24.0 in.) Height: 70.7 cm (27.8 in.) Depth: 99.5 cm (39.0 in.) |
Regulatory approvals/marks |
CE, CB, NRTL (CAN/US), RCM |
Software |
Systems supported on waters_connect and MassLynx™ version 4.2 or later |
System setup and method development |
System parameter checks and alerts Integrated sample/calibrant delivery system + programmable divert valve Automated mass calibration Automated sample tuning Automated MRM method development UPLC-MS/MS System Check-on-column performance test |
Automated MRM scheduling (acquisition rate assignment) |
Dwell time, inter-channel delay time and inter-scan delay time for individual channelsin a Multiple MRM experiment can be automatically assigned (using the Auto-Dwell feature) to ensure that the optimal number of MRM data points per chromatographic peak are acquired. The Auto-Dwell feature dynamically optimizes MRM cycle times to accommodate retention time windows that overlap. This greatly simplifies MRM method creation, irrespective of the number of compounds in a single assay, while at the same time ensuring the very best quantitative performance for every experiment |
waters_connect software |
The waters_connect software provides a modern user experience with a HUB design and apps that provide a consistent connected user experience across all applications. It is built for applications with convenient access to scientific apps allowing accelerated time-to-results and result quality. There are common utilities that complete the end-to-end workflow and help increase productivity and efficiency. Confidently report results with accurate, reliable, regulation-standard data from application-focused quantitative workflows with built in traceability for utmost integrity. |
Acquisition modes |
Full scan MS Product ion scan Precursor ion scan Constant neutral loss scan Multiple reaction monitoring (MRM) Simultaneous Full scan and MRM (RADAR) |
RADAR |
An information rich acquisition approach that allows you to collect highly specific quantitative data for target compounds while providing the ability to visualize all other components |
Mass range |
2 to 2048 m/z |
Compare Xevo TQ Systems
|
Xevo TQ-S cronosXevo TQ-S cronos
|
Xevo TQ-S microXevo TQ-S micro
|
Xevo TQ-XSXevo TQ-XS
|
Xevo TQ AbsoluteXevo TQ Absolute
|
---|---|---|---|---|
Dimensions (w x h x d) |
Dimensions (w x h x d) |
Dimensions (w x h x d) |
Dimensions (w x h x d) |
Dimensions (w x h x d) |
Dimensions (w x h x d) |
35.6 x 60 x 93 cm |
35.6 x 60 x 93 cm |
61 x 70.7 x 99.5 cm |
43 x 79 x 96 cm |
Sensitivity key |
Sensitivity key |
Sensitivity key |
Sensitivity key |
Sensitivity key |
Sensitivity key |
★★ |
★★★ |
★★★★ |
★★★★★ |
Mass range |
Mass range |
Mass range |
Mass range |
Mass range |
Mass range |
2 to 2048 m/z |
2 to 2048 m/z |
2 to 2048 m/z |
2 to 2048 m/z |
Chromatographic configuration compatibility |
Chromatographic configuration compatibility |
Chromatographic configuration compatibility |
Chromatographic configuration compatibility |
Chromatographic configuration compatibility |
Chromatographic configuration compatibility |
ACQUITY Arc* ACQUITY Premier ACQUITY UPC2* ACQUITY UPLC ACQUITY UPLC M-Class* |
ACQUITY Premier ACQUITY UPC2* ACQUITY UPLC ACQUITY UPLC M-Class* APGC* |
ACQUITY Premier ACQUITY UPC2* ACQUITY UPLC ACQUITY UPLC M-Class* APGC* |
ACQUITY Premier ACQUITY UPLC ACQUITY UPLC M-Class* APGC* |
Ion sources compatibility |
Ion sources compatibility |
Ion sources compatibility |
Ion sources compatibility |
Ion sources compatibility |
Ion sources compatibility |
APCI ASAP* ESCi* ESI |
APCI APGC* ASAP* ESCi* ESI ionKey* Nanoflow* |
APCI APGC* ASAP* ESCi* ESI ionKey* Nanoflow* |
APCI APGC* ASAP* ESCi* ESI Nanoflow* |
Acquisition modes |
Acquisition modes |
Acquisition modes |
Acquisition modes |
Acquisition modes |
Acquisition modes |
Full scan Product scan Precursor ion scan Constant neutral loss scan Multiple reaction monitoring (MRM) Simultaneous Full Scan and MRM (RADAR) |
Full scan Product scan Precursor ion scan Constant neutral loss scan Multiple reaction monitoring (MRM) Simultaneous Full Scan and MRM (RADAR) |
Full scan Product scan Precursor ion scan Constant neutral loss scan Multiple reaction monitoring (MRM) Simultaneous Full Scan and MRM (RADAR) |
Full scan Product scan Precursor ion scan Constant neutral loss scan Multiple reaction monitoring (MRM) Simultaneous Full Scan and MRM (RADAR) |
Detector ** |
Detector ** |
Detector ** |
Detector ** |
Detector ** |
Detector ** |
Low noise, off axis, long life photomultiplier** |
Low noise, off axis, long life photomultiplier** |
Low noise, off axis, long life photomultiplier** |
Low noise, off axis, long life photomultiplier** |
Ion source transfer optics |
Ion source transfer optics |
Ion source transfer optics |
Ion source transfer optics |
Ion source transfer optics |
Ion source transfer optics |
StepWave XS |
StepWave XS |
||
MRM speed |
MRM speed |
MRM speed |
MRM speed |
MRM speed |
MRM speed |
555 MRM/ sec |
555 MRM/ sec |
500 MRM/ sec |
500 MRM/ sec |
Regulatory approval *** |
Regulatory approval *** |
Regulatory approval *** |
Regulatory approval *** |
Regulatory approval *** |
Regulatory approval *** |
||||
Third party software interfaces |
Third party software interfaces |
Third party software interfaces |
Third party software interfaces |
Third party software interfaces |
Third party software interfaces |
LIMS interface MassLynx SkyLine interface |
LIMS interface MassLynx SkyLine interface |
LIMS interface MassLynx SkyLine interface |
LIMS interface MassLynx SkyLine interface |
MassLynx security |
MassLynx security |
MassLynx security |
MassLynx security |
MassLynx security |
MassLynx security |
Yes |
Yes |
Yes |
Yes |
Software options |
Software options |
Software options |
Software options |
Software options |
Software options |
|
|
|
|
* Not available with waters_connect
** Less than 1% of Waters’ tandem quadrupole mass spectrometers require a detector replacement on an annual basis. [Source: Waters’ internal data on the service history of its tandem quadrupole mass spectrometers launched between 2006 and 2022]
*** Regulated approval marks include CE, CB, NRTL (Canada/USA), RCM
Overview
- Expanding your efficiencies: Maximize your laboratory’s potential in high sensitivity quantitative analysis by extending your capabilities, confidently and productively
- Performance that’s proven: Trust the proven Xevo TQ-XS to meet the analytical demands of your challenging applications , injection after injection
- Digesting your data: Reduce the burden in data handling with flexible and adaptable software solutions to meet your application and quality system needs
- Supporting your success: Have confidence that you will exceed your analytical requirements using Waters end to end solutions with flexible service and application focused training and support
Recommended Use: Quantitative analysis where high sensitivity instrument performance is required (e.g., to reach low level concentrations (ppt)).
Features Header
Expand your analytical capabilities with enhanced sensitivity
Delivering the next step in reliable sensitivity, the Xevo TQ-XS enables your laboratory to expand your analytical capacity and productivity. Whether seeking more sensitivity to detect your analytes routinely, looking to extend your scope of analytes with increased confidence or revise your workflow to reduce time and costs, explore what Xevo TQ-XS, coupled with ACQUITY UPLC and ACQUITY Premier Systems can offer your lab.
Proven performance you can trust for your challenging analyses
Whether looking to streamline your methods or advance your laboratory’s performance, explore how Xevo TQ-XS, coupled with LC (UPLC), GC (APGC) or SFC (UPC2) can benefit your challenging applications. Trust the proven Xevo TQ-XS to meet your analytical demands, injection after injection.
Software solutions to overcome a common bottleneck
While quantitation of targeted analytes can be a routine experiment, the volume of data acquired and generated for processing, review and management can be significant. Waters’ informatics platforms offer extensive toolsets to support efficient and compliant data handling to support your 21 CFR 11 and ISO 17025 environments.
Accelerating your success with award winning service
Ensure your laboratory runs efficiently and is ready to address the opportunities of tomorrow with Waters comprehensive analytical solutions with expert training (APS) and flexible and cost-effective solutions to advance your business with system service (FlexCHOICE), trade-ins and technological upgrades (FlexUP).