2432 Conductivity Detector for HPLC Systems

2432 Conductivity Detector for HPLC Systems

Exceptional sensitivity and stability for challenging separations

Exceptional sensitivity and stability for challenging separations

Single-column and suppressor-based ion chromatography require exceptional sensitivity and stability. The 2432 Conductivity Detector, in a non-suppressed ion chromatography method, provides a highly sensitive and stable performance.

The cell design of the 2432 Conductivity Detector diminishes apparent void volume disturbances for more reliable peak quantitation. Precise temperature control of the flow cell coupled with the detector’s ability to collect absolute and auto-zeroed data eliminate baseline drift and enable the chromatographer to perform other tasks. 

2432 Conductivity Detector for HPLC Systems 2432 Conductivity Detector for HPLC Systems

Specifications

Measuring range

0 to 10,000 μS/cm without range switching

Drift

<0.5%/hr

Noise

≤0.005 μS/cm

Temperature control

20 °C–50 °C in steps of 5 °C and Off

Temperature stability

±0.1 °C

Sampling rate

10 points/s

Electrodes

Ring-shaped electrodes made from stainless-steel

Cell volume

0.8 μL

Pressure limit

725 psi

Wetted materials

Chemically inert PCTFE and stainless-steel

Overview

  • Achieve high sensitivity and exceptional stability with temperature-controlled flow cell
  • Reduce flow path volume for narrow-bore applications
  • Increase operational uptime with self and user diagnostics
  • Ensure a precise conductivity base range with user-adjustable cell constant

Recommended Use: For single-column ion chromatography requiring high stability and sensitivity.


Features Header

Features Header






Achieve reliable peak quantitation and maintain stability

The 2432 Conductivity Detector features exceptional sensitivity and stability for single-column or suppressor-based ion chromatography. The 2432 cell design diminishes apparent void volume disturbances and offers more reliable peak quantitation. Additionally, the 2432 Conductivity Detector’s temperature control combined with autozero capabilities ensure maintained baseline stability during your analysis.





Resources

Documents

Documents


Support

Support


Related

Providing versatile, dependable performance for analytical labs, the Alliance HPLC family meets the rigorous requirements of routine chromatography and the performance standards of new-product research and method development.

The ACQUITY UPLC H-Class PLUS System delivers the flexibility and precision of quaternary or binary solvent blending with the advanced performance expected of UPLC separations: high resolution, sensitivity and improved throughput.

Get HPLC and UHPLC method compatibility at the flip of a switch with this versatile, modern LC system.
Back To Top Back To Top