For research use only. Not for use in diagnostic procedures.
This is an Application Brief and does not contain a detailed Experimental section.
This application brief showcase the complementary nature of Full Spectrum Molecular Imaging on the SYNAPT XS, demonstrating the benefit of this updated fully integrated solution to MS imaging customers.
The only HRMS platform to feature both fully integrated traditional MALDI and new and improved DESI XS sources, providing a flexible, comprehensive, and simple solution for holistic molecular MS imaging.
Full Spectrum Molecular Imaging (FSMI) combines several analytical techniques in a single platform to probe a wide spectrum of spatially distributed molecular ions. This is used to understand molecular function and physiology or to monitor the distribution of drug compounds throughout a tissue or organism. Since 2015, the SYNAPT family platforms have employed this combined type of workflow to enable MS imaging customers to have the most comprehensive imaging solution possible for their wide-ranging discovery needs.
Full Spectrum Molecular Imaging systems utilize a combination of mass spectrometry techniques that are well suited to analyze particular types of molecules (peptides, lipids, small molecule metabolites, sugars, etc.). See Figure 3 for the relative benefits of MALDI and DESI analyses.
These techniques complement each other to deliver the most comprehensive level of information possible with MS imaging (see Figure 1 for FSMI workflow for tissue imaging).
By integrating DESI, MALDI, and ion mobility mass spectrometry techniques with a single informatics solution, Waters Full Spectrum Molecular Imaging system provides detailed molecular information that exceeds any single MS imaging technique currently available.
To augment MS imaging capabilities, we have significantly enhanced the FSMI system solution, both with the introduction of the SYNAPT XS, the state-of-the-art HRMS ion mobility-enabled mass spectrometer, and the new and improved DESI XS source. In addition to this, we have responded to customer requests by improving the Waters High Definition Imaging (HDI) Software with advances in data processing speed for large data sets, improving data alignment for HDMSE data, and removing limits on the amount of data that can be processed and loaded into the software.
Benefits of the FSMI systems include:
Full Spectrum Molecular Imaging is only available on the SYNAPT family IMS-enabled MS system solutions. These systems can also be used as standard ESI-Tof instruments for other UPLC-MS based applications by easily changing system configuration.
Figure 2 shows an example of FSMI data acquired on the SYNAPT XS highlighting complementary images generated from both MALDI and DESI data. These images highlight different lipid profiles between the cortex and the medulla of the kidney, which are DESI or MALDI analysis. It also emphasises that that small molecules such as metabolites are more easily detected with DESI than MALDI.
MS imaging publications also acknowledge the complementary nature of FSMI and have shown methods and workflows for complete comparison between the techniques and for their intra-technique variables such as polarity, MALDI matrix, and DESI solvent system.¹
With the increased use of MS imaging in drug development,² which allows the mapping of drugs and metabolites within tissue, it is important to understand the complementary nature of DESI and MALDI ionization techniques. Figure 4 reports the results from a range of pharmaceutical compounds, analyzed by DESI and MALDI, on the same mass spectrometer. It highlights the power of having both ionization capabilities to increase molecular coverage. Differences in ionization efficiency, limit of detection (LOD) and ease of sample preparation were all observed.
The relative individual benefits of the techniques incorporated into a Full Spectrum Molecular Imaging system shown in Figure 5, are:
DESI imaging utilizes a charged solvent spray to desorb ions directly from the surface of a sample without any sample preparation. Waters has taken traditional DESI imaging and enhanced its capabilities to provide new levels of usability and performance by adding innovation to this imaging technique. Some of the advantages of using DESI imaging include:
MALDI imaging utilizes a laser based, direct ionization method to analyze molecules from a chemical matrix coated sample. MALDI imaging is considered the standard technique for imaging applications using MS. The technique provides:
Ion mobility can add another dimension of molecular separation to imaging studies. This technique is capable of resolving molecules for analysis based on their size and shape. Useful for removing interferences or isolating target molecules for more intense scrutiny, ion mobility is a unique method to enhance the analytical capabilities of an imaging system with even greater molecular discrimination. Ion mobility can be used to:
Full Spectrum Molecular Imaging capabilities allow visualization of wider range of molecular ions and provide key insights into the underlying mechanisms of cancer, cardiovascular, and neuro-degenerative diseases. In other studies, Full Spectrum Molecular Imaging can be used to identify different tissue types, differentiate diseased and normal tissue, and identify the boundary of healthy and diseased tissue based on their molecular composition. With the performance improvements obtained with the combination of SYNAPT XS and DESI XS, the Waters Full Spectrum Molecular Imaging solution delivers greater benefit than ever before for all imaging needs.
720006851, May 2020