Alliance iS HPLC System
A new era of intuitive simplicity
Quality Control (QC) labs face stringent, ever-evolving compliance and data quality requirements to release products within tighter timelines and budgets. These problems become exaggerated due to staff turnover and training requirements.
To address these problems, the Alliance iS HPLC System elevates your QC lab with first-time right results, shortened release cycles, and fewer investigations by:
- Reducing human errors by up to 40%* through innovative system intelligence that addresses errors before they can occur
- Enhancing productivity and asset management with safeguards to ensure correct system performance
- Maximizing system uptime and minimizing service intervention
*based on Waters’ market research in 2022, surveying 56 global Pharma QC labs running >25 systems.
Specifications
Maximum operating pressure |
10,000 psi |
pH range |
1 to 13 |
Operating flow rate range |
0.001 to 10.000 mL/min |
Injection type |
Flow-through needle |
Sample flow path |
Stainless steel |
Sample carryover |
≤0.002% [Caffeine] under UV conditions |
Sample compartment |
4 to 40 °C |
Pump options |
Quaternary |
Solvent conditioning |
Passive pre-heating |
Column tracking |
Yes, with RFID enabled eConnect Waters Columns |
Column capacity |
1 column up to 300 mm length, up to 8 mm internal diameter (I.D) |
Maximum sample capacity (any three of the following) |
48-position, 2.00-mL vial holder 54-position, 2.00-mL vial holder 96-well plate 384-well plate 48-position, 0.65-mL micro-centrifuge tube plate 24-position, 1.50-mL micro-centrifuge plate |
Detector options |
TUV Detector |
Informatics compatibility |
Empower Chromatography Data System (CDS) (Feature Release 4 with Windows 10 and later) |
Physical Specifications |
Height: 74.2 cm (29.23 in.) Width: 49.9 cm (19.64 in.) Depth: 63.5 cm (24.99 in.) Weight: 72.5 kg (160.0 lbs.) |
Overview
- Multiply the productivity and efficiency of your QC lab by reducing human error with hardware and intuitive touchscreen tools that stop unacceptable runs before they can occur
- Secure your data integrity and consistency and maximize system uptime through consistent user operations with guided operational tools that ensure proper system preparation
- Amplify your lab’s return on investment (ROI) on equipment and analysts through enhanced situational awareness and automated system health monitoring that quickly communicates system status and streamlines decision making
- Reduce unexpected system downtime and shorten the break-fix cycle with guided troubleshooting and maintenance and enhanced component serviceability, all available on the instrument touchscreen
- Count on repeatable global method performance with improved thermal stability, hardware compatibility with legacy methods, and intelligent method translator tools
- Reduce carryover and improve temperature stability with the latest in Waters historically dependable instrument technology
Recommended Use: For QC labs with a drive to reduce human errors and unexpected downtime.
Features Header
Meet your new lab ally
Mistakes in the lab come in many forms: forgotten samples, incorrect solvent levels, incorrect tightening of system fittings, or not verifying correct system performance. Regardless, mistakes lead to repeated procedures and possibly time-consuming investigations.
Built for Empower Software, the Alliance iS HPLC System coupled with Empower CDS and Empower LMS serves as your assistant – preventing common errors with pre-run verification of the correct column, vials, and plates, as well as solvent levels and expiration dates.
Additionally, the Alliance iS HPLC System’s tool-free fittings, clearly labeled and organized solvent lines, and auto-recognition of Waters eConnect HPLC Columns prevent leaks and user errors when setting up the system for analysis. Integrated hardware components standardize your fleet to ensure proper system configurations for your analysis.
Enjoy stress-free analysis
Employee turnover makes training a continual challenge and can lead to inconsistencies and decreased productivity. The Alliance iS HPLC System keeps you and your lab stress-free and running smoothly with an intuitive touchscreen that supports learning the system and producing consistent, quality results.
The instrument touchscreen interface provides at-instrument guided workflows for system start-up, shutdown, and priming – helping to ensure all your users are preparing their systems sufficiently and identically.
Intuitively simple for informed decisions
Managers and analysts need to make quick decisions. Ambiguous system performance status impedes the ability to select, maintain, and service instruments.
The Alliance iS HPLC System is designed with intuitive system mechanisms to give fast feedback that your team can act upon to get the best return on investment of your equipment. Using the combination of status lights on the system, the touchscreen interface, Empower Software, and integration with waters_connect System Monitoring, your team can immediately understand your system operation. Additionally, your lab can leverage health monitoring tools to dive deeper into the crucial performance parameters of your system.
Maximize system uptime with help at your fingertips
Nothing disrupts operations like unexpected system downtime. The Alliance iS HPLC System is built upon Waters strong legacy of reliable instrument performance while also improving upon previous generations. Improvements to our injector, mixer, column manager, check valves, and detectors maximize the reliability of your instrument.
The touchscreen interface also provides guided troubleshooting and guided maintenance, and the system has been optimized to provide easy access to serviceable components. The touchscreen interface also enables easy access to the Waters service department with quick and easy access to the Waters Help Center.
With the Alliance iS HPLC System, you can ensure your system will be more reliable than ever while minimizing unscheduled downtime should anything unexpected occur.
Support your compliant, global business network
Your systems need to support both legacy and new methods that can be operated repeatably anywhere in the world while meeting regulatory requirements. These requirements can also place a large burden on your analysts, but failing to perform necessary tasks could put your organization at risk.
The Alliance iS HPLC System features improved enhanced temperature control in the sample manager, column manager, and detector to match global needs. Additionally, when coupled with Empower Software Solutions and eConnect HPLC Columns, analysts gain access to new features:
- Intelligent Method Translator App (iMTA) to assist with method migration from other systems
- Method Matching App, which warns users from trying to run methods the system is not optimized to perform
- System Audit Trail, where actions performed on the touchscreen interface are automatically logged into Empower audit trails for enhanced compliance tracking
- Automated column history tracking
Resources
Documents
Explore documents, videos, and other resources to support your Waters solution.