ACQUITY Premier System with Multi-Dimensional Technology

ACQUITY Premier System with Multi-Dimensional Technology

Multi-dimensional technology for increased UPLC/UHPLC resolution when you need it

Multi-dimensional technology for increased UPLC/UHPLC resolution when you need it

The ACQUITY Premier System with Multi-Dimensional Technology offers the lowest dispersion system for maximum peak capacity with the most reliable, highest performing solvent managers and valve compartments on the market, ensuring accuracy and precision of the entire assay. This multi-dimensional system configuration allows chemists to increase sensitivity and selectivity, eliminate unwanted interference, and characterize the most complex samples.

Additionally, the system extends the performance of MaxPeak High Performance Surfaces (HPS) Technology beyond the column, offering improvements in separation and detection of metal-sensitive analytes.

ACQUITY Premier System with Multi-Dimensional Technology ACQUITY Premier System with Multi-Dimensional Technology

Specifications

Number of solvents

Up to four, in any combination of two: Al or A2 and B1 or B2

Solvent conditioning

Five vacuum degasser, one allocated for injector purge solvent

Operating flow rate range

0.001 to 2.000 mL/min, in 0.001 mL increments (firmware v1.71 and later)

Compressibility compensation

Automatic and continuous, no user intervention required

Plunger seal wash

Integral, active, programmable

Gradient profiles

11 gradient curves [including linear, step (2), concave (4), and convex(4)]

Wet prime

Automatic

Maximum operating pressure

15,000 psi up to 1 mL/min, 9000 psi up to 2 mL/min per pump, not more than 15,000 psi total

Composition accuracy

±0.5% absolute (full scale) from 5% to 95% of flow rates from 0.50 to 2.00 mL/min

Composition precision

0.15% RSD or ±0.01 min SD, whichever is greater, based on retention time

Flow precision

0.075% RSD or ±0.02 min SD, or 1.00 s for run times less than 1.00 min based on retention time or volumetric measures (0.5 to 2.0 mL/min)

Primary wetted materials

Titanium, PPS, fluoropolymer, fluoroelastomer, UHMWPE blend, sapphire, ruby, zirconia, Nitronic 60, DLC, PEEK and PEEK blend, Inconel 600, FEP

Solvent capacity

Blend up to four solvents in any combination (standard); total capacity of nine solvents with integrated solvent select valve (optional)

Number of fluidic paths

Three (Path 1, Path 2, and waste), with Arc™ Multi-flow path technology (standard)

Dwell volume selection

Automated with Arc Multi-flow path technology

Solvent conditioning

Integrated vacuum degassing, four chambers

Gradient formation

Low-pressure mixing, quaternary gradient

Gradient profiles

11 gradient curves [including linear, step (2), concave (4), and convex (4)]

Check valves

Passive check valves

Flow accuracy

+/- 1.0% at 0.5, 3.0, and 5.0 mL/min

Flow precision

≤0.075% RSD or +/-0.020 min SD, whichever is greater, based on six replicates [60:40 water:methanol pre-mixed; 1.5 mL/min; alkylphenone mix; 24.0 μL injection volume; CORTECS C18 2.7 μm, 4.6 x 50 mm; 35 °C; UV @254 nm]

Composition ripple

≤0.5 mAU [mobile phase containing 0.1% TFA in water/acetonitrile; 1.5 mL/min; CORTECS C18 2.7 μm, 4.6 x 50 mm; 35 °C; UV @214 nm]

Composition accuracy

+/- 0.5% absolute (full scale) from 5 to 95%; 0.5 to 5.0 mL/min [methanol; methanol with 5.0 mg/mL caffeine step gradient; UV @273 nm]

Composition precision

+/- 0.15% RSD or 0.04 min SD, whichever is greater based on six replicate injections [60:40 water:methanol via Auto•Blend™ Technology; 0.5 mL/min; alkylphenone mix; 24.0 μL injection volume; CORTECS C18 2.7 μm, 4.6 x 50 mm; 35 °C; UV @254 nm]

Compressibility compensation

Automatic and continuous

Priming

Wet priming can run at flow rates up to 10 mL/min

Pump seal wash

Standard

Primary wetted materials

316L stainless-steel, PPS, fluoropolymer, UHMWPE blend, sapphire, ruby, zirconia, DLC, PEEK and PEEK blend, titanium alloy

Injection volume range

0.1 to 10.0 μL as standard

Up to 1000.0 μL with optional extension loops

Accuracy (aspiration)

±0.2 μL (measured by fluid weight removed from vial with 10 μL injections averaged over 20 injections using standard 100 μL syringe)

Linearity†

≥999 (standard needle)

Precision†

≤0.25% RSD, 5 to 100 μL

Number of sample plates

Any two of the following:

96 and 384 microtiter plates

48-position 2.00 mL vial plates

48-position 0.65 mL micro-centrifuge tube plates

24-position 1.50 mL micro-centrifuge tube plates

Maximum sample capacity

768 in two 384-well plates or 96 in 2 mL vial holders, four additional positions for dilution functions

Sample compartment temp.

4.0 to 40.0 °C, settable in 0.1 °C increment

Temperature accuracy

±0.5 °C at sensor

Temperature stability

±1.0 °C at sensor

Sample manager heat time

≤30 min ambient -40 °C

Injection needle wash

Integral, active, programmable

Minimum sample required

3 μL residual, using Waters Total Recovery 2 mL vials (zero offset)

Sample carryover†

≤0.002% caffeine (UV)

≤0.002% sulphadimethoxine (MS)

Advanced sample

manager capabilities

Auto-dilution, auto-addition, and load-ahead

Primary wetted materials

Vespel SCP, PEEK blend, DLC, and HPS

†For specific test conditions, contact your Waters sales representative.

Column capacity CM-A

Two columns, as standard (maximum length of 150 mm with filter or guard column), or four columns (maximum length of 50 mm) can be supported with optional tubing kit, up to 4.6 mm internal diameter (I.D.)

Multidimensional valves

Two six-port, two-position valves

Column compartment(s)

temperature range

4.0 to 90.0 °C, settable in 0.1 °C increments

Two independent heat/cool zones per module

Column compartment(s)

temperature accuracy

±0.5 °C at sensor

Column compartment(s)

temperature stability

±0.3 °C at sensor

Column compartment heat time

≤15 min ambient -60 °C

Column compartment cool time

≤15 min 60–20 °C

Solvent conditioning

Active pre-heating as standard

Column tracking

eCord™ Technology column information management tracks and archives column usage history for one column

External communication

Ethernet interfacing via RJ45 connection to host PC with BSM, or Column Manager and UPLC™ detectors and mass spectrometers

Event inputs/outputs

Rear panel contact closure and/or TTL inputs/outputs

External control

MassLynx™ v4.1 with OpenLynx™ Open Access, with specific SCN releases

User diagnostics

Available through software on host PC; system control via console software

Unattended operation

Leak sensors on supported modules, full diagnostic data captured through console software

Acoustic noise

<62 dBA

Operating temperature range

4.0 to 40.0 °C (39.2 to 104.0 °F)

Operating humidity range

20% to 80%, non-condensing

Voltage

100 to 240 VAC

Frequency

50 to 60 Hz

ACQUITY Premier Multi-Dimensional

System with FTN-H, one Binary

Solvent Manager, one Quaternary

Solvent Manager, and

a Column Manager

Width: 83.8 cm (33 in.)

Depth: 86.4 cm (34 in.)

Height: 103.4 cm (40.7 in.)

Note: Dimensions are listed with only components listed above.

Part Title

Part Number

ACQUITY Premier Multi-Dimensional System

Varies, based on detailed configuration

Overview

  • Achieve successful multi-dimensional UPLC and UHPLC experiments quicker and with robustness and more confidence with the help of ready-to-use configurations
  • Attain top-tier selectivity and sensitivity by using the ACQUITY Premier Systems with Multi-Dimensional Technology with proven chemistries, including the MaxPeak Premier Columns
  • Benefit from MaxPeak HPS Technology connected to the ACQUITY Premier Systems with an inert flow path

Recommended Use: To eliminate unwanted interferences and increase peak capacity and resolution for characterization of the most complex samples.


Features Header

Features Header






Functionality that meets all your laboratory’s needs

UPLC technology’s benefits like resolution, sensitivity, and throughput are crucial in multi-dimensional LC applications. Waters ACQUITY Premier Systems with Multi-Dimensional Technology is purpose-built to provide reproducible and consistent results in everything, from plumbing to software to valve control.

ACQUITY Premier Multi-Dimensional Systems can effectively perform functions such as trapping, heart cutting, parallel column regeneration, at-column dilution, and time de-coupled chromatography – all enhancing your ability to eliminate unwanted interferences, increase peak capacity and resolution for characterizing the most complex samples, and improve assay ruggedness and overall analysis speed.