IonSABRE APCI Probe Accessory

IonSABRE APCI Probe Accessory

More effectively analyze high-polarity compounds

More effectively analyze high-polarity compounds

Atmospheric Pressure Chemical Ionization (APCI) is an effective method for analyzing lower-polarity compounds. The high-efficiency IonSABRE™APCI probe offers significant improvements in sensitivity compared with earlier versions of probe, particularly at higher liquid flow rates.

IonSABRE APCI Probe Accessory

Overview

Ionization Process

With APCI, the sample stream is nebulised and analytes are desolvated using a combination of gas flow and high temperatures. The desolvated compounds are ionized by charge transfer as they pass through a plasma created by a corona discharge. Flow rates up to 2 mL/min are acceptable.

The IonSABRE APCI probe with thermally enhanced heater design provides improved heat distribution and sample vaporization. The support gas flow also maximizes transmission of sample droplets into the ion source.

Together, these features provide optimum APCI performance leading to superior limits of quantitation in compound quantification and identification studies.



Instrument Compatibility

The IonSABRE APCI probe is available for the following MS instruments:

  • ACQUITY™ SQD/TQD, 3100, SQ Detector 2, Xevo™ TQD
  • Xevo TQ MS, Xevo TQ-S, Xevo TQ-S micro
  • Xevo G2 QTof, Xevo G2-S QTof, Xevo G2-XS QTof
  • Xevo G2 Tof, Xevo G2-S Tof, Xevo G2-XS Tof
  • Xevo TQ-XS
  • MALDI SYNAPT MS, MALDI SYNAPT HDMS
  • SYNAPT G2 MS, SYNAPT G2 HDMS, MALDI SYNAPT G2 MS, MALDI SYNAPT G2 HDMS
  • (MALDI) SYNAPT G2-S MS, (MALDI) SYNAPT G2-S HDMS
  • (MALDI) SYNAPT G2-Si MS, (MALDI) SYNAPT G2-Si HDMS

*An additional conversion kit is included with the LCT Premier IonSABRE probe option to allow Ion Sabre APCI Exact Mass experiments.


Equipment and Installation

The accessory kit comprises:

  • IonSABRE probe and Corona pin
  • Spare parts kit and User operation guide
  • Free-standing power supply unit ( selected instrument only)

Although the accessory is easy to install, Waters strongly recommend installation and operation confirmation/training by a Field Service Engineer.

Resources

Documents

Documents


Support

Support


Related

A benchtop QTof mass spectrometer incorporating the XS Collision Cell for enhanced sensitivity and selectivity, resulting in the highest quality, most comprehensive qualitative information together with the ultimate in quantitative performance.

A robust and sensitive tandem quadrupole MS with compact design, featuring robust performance with a wide dynamic range and high rates of data acquisition.

The SQ Detector 2 is an advanced benchtop single quadrupole mass detector designed for high performance LC-MS applications. With a wide range of ionization options including APPI and ASAP, the SQ Detector is ideally suited to qual/quan applications.

The Xevo TQD Tandem, commonly known as Triple Quadrupole Mass Spectrometer is designed for routine quantitative UPLC-MS/MS applications, so you can confidently quantify and confirm trace components in the most complex of samples.

The Xevo TQ-S provides high sensitivity for quantitative applications, with patented StepWave technology, to accurately quantify components at low levels in the most complex samples.

The only way to access multiple dimensions of resolution for the highest levels of separation, specificity and confidence in analysis. A uniquely powerful and versatile platform for imaging, life science research and chemical material characterization.

Routine high resolution MALDI MS/MS performance and unparalleled analytical versatility for a wide range of applications - from imaging and life science research to characterization of chemical materials.

SYNAPT G2-Si MS provides the most uncompromising High Resolution UPLC-MS/MS performance, with the greatest versatility and upgrade option to access 3 dimensions of resolution for the ultimate in discovery power.
Back To Top Back To Top