LC Prep AutoPurification System

LC Prep AutoPurification System

Purify your compounds with confidence

Purify your compounds with confidence

Preparative-scale chromatography is critical in applications where compounds must be synthesized, identified, isolated, purified, characterized, screened, and tested. Waters AutoPurification Systems offer scalable prep configurations, whether you want the specificity of mass-directed purification or inclusiveness of a UV system.

The LC Prep AutoPurification System provides you with the flexibility of high-throughput parallel runs for selective mass-directed fraction collection from hundreds of samples. With the LC Prep AutoPurification System, your lab can run samples around the clock all with unprecedented versatility and consistency.

LC Prep Autopurification System with System Fluidics Organizer (SFO) and ACQUITY QDa Mass Detector. LC Prep AutoPurification System

Specifications

External Control: MassLynx Software with FractionLynx

2545 BGM

2535 QGM

2545 QGM

2555 QGM

Flow rate range

0.5 to 150.0 mL/min

0.5 to 50.0 mL/min

0.5 to 150 mL/min

4.0 to 300.0 mL/min 

Delay volume

0.35 mL

<6.0 mL

<6.5 mL

<13 mL

Number of solvents

Up to 4: A1 or A2 and B1 or B2

Up to 4: A, B, C, D

Up to 4: A, B, C, D

Up to 4: A, B, C, D

Max pressure

6000 psi up to 100 mL/min; Rolloff to 5000 psi at 150 mL/min

6000 psi

6000 psi up to 100 mL/min; Rolloff to 5000 psi at 150 mL/min

3000 psi up to 200 mL/min; Rolloff to 2500 psi at 150 mL/min

Size (W x H x D, cm)

28 x 43.2 x 66

28 x 43.2 x 66

28 x 43.2 x 66

28 x 43.2 x 66

Weight (kg)

39.5

39.5

39.5

39.5

3767

Fume hood

Optional

Injector volume (fixed sample loop)

Analytical valve: 20 µL loop standard

Preparative valve: 1.0 mL standard

Optional loop sizes include: 100 μL, 1.0 mL, 2.0 mL, 5.0 mL, 10 mL, 30 mL

Syringe sizes

1.0 mL (standard), 2.5 mL, 5 mL, and 12.5 mL

Size (W x H x D, cm)

95.9 x 106 x 69.2

Weight (kg)

86.2

Bed layout (W x D, cm)

86.6 x 38.1

SFO

Switching valves

6-, 8-, and 10-port valves for automated flow switching

Analytical to prep

6-port valve

Column selection

8-port valve for switching between 3 analytical columns

10-port valve for switching between 2 prep columns

Size (W x H x D, cm)

28.2 x 42.7 x 52.3

Weight (kg)

10

3767

WFCIII

Rack options

Variety of racks available, bed is customizable

Variety of racks available, bed is customizable

Fraction capacity

15 MTP, up to 544 test tubes

4 MTP, 120 test tubes

Size (W x H x D, cm)

95.9 x 106 x 69.2

28.6 x 35.9 x 33.5

Weight (kg)

86.2

7

Overview

  • Take the complexity out of purification with versatile Waters solutions that can purify microgram to multigram quantities
  • Automatically process hundreds of samples - or just a few
  • Improve your ability to manage increasing workload demands, including unattended instrument operation, with robust and reliable systems
  • Achieve easy scale-up from analytical to preparative chromatography with flexible configurations
  • Automate the collection of detected fractions, track samples and fractions, and then see the data in an easy-to-view format with FractionLynx Application Manager
  • More easily manage solvents and samples, whether you do manual or automated injections, with user-friendly console and software features
  • Bring the latest technologies to your lab with easy-to-upgrade systems

Recommended Use: For purifying your compounds with the specificity of mass-directed purification or inclusiveness of UV detection.


Features Header

Features Header






MS- or UV-directed fraction collection

With the AutoPurification HPLC/UV System, your lab can run samples around the clock with unprecedented versatility and consistency. The AutoPurification HPLC-MS System provides you with the flexibility of using high-throughput parallel runs for selective mass-directed fraction collection from hundreds of samples.

The AutoPurification HPLC-MS System with the ACQUITY QDa Mass Detector or the SQ Detector 2 mass spectrometer is designed for everyday mass-directed purification, so you can collect more of what you want more affordably and easily. With the System Fluidics Organizer, you can easily manage column selection and column regeneration. Achieve full automation and high throughput capabilities with the system's fluidics layout, and leverage enhanced software features and Waters proprietary Optimum Bed Density (OBD) Column technology for maximum efficiency. 


Open access purification

Whether your company manages preparative LC in a centralized lab or provides purification capabilities in an open access environment, easy-to-use systems and software from Waters allow you to run samples with unattended system operation. This improves productivity by enabling chemists to focus on their results rather than on the instrument.

With Waters systems and software, purification is easier to manage because:

  • Chemists can walk up to a system, enter their sample, and have results delivered to their desktop, while an administrator monitors the system and manages instrument access with Open Access software
  • Fraction collection software provides full-cycle automation, from evaluation and setting collection thresholds to purification to fraction analysis
  • Unique method filtering software enables the user to quickly choose a method from the existing library of methods
  • Labs can automatically generate gradients without having to manually buffer solvent concentration, and build column clean-up and system flushing into your method
  • A solvent monitoring system enables you to use multiple solvent reservoirs with automated warning responses about instrument status and intelligent shut-down available
  • A remote system status monitor tracks the sample queue, instrument, and solvent and waste container status online

Automated fraction collection and analysis

Managing Fraction Collection
FractionLynx Application Manager provides full-cycle automation for purification, from evaluating and setting collection thresholds, to collection of the detected fractions, to tracking the samples and fractions, to presentation of the data in an easy-to-view format. The software can trigger collection using a variety of detector signals including UV/Visible, evaporative light scattering (ELS), mass spectrometry (MS), and analog. Other fraction collection options include one-to-one mapping to retain plate format, secondary collection of peaks that are not of primary concern but not classified as waste, and waste collection.

Sample Evaluation
AutoPurify, a feature of the FractionLynx Application Manager, further automates this process by detecting the presence of the target compound and measures its purity to determine the purification process, from initial analytical screening, through purification, to the analysis of the collected fractions. AutoPurify automatically selects a focused preparative gradient based on an analytical screening run, which provides better quality purification and eliminates the need for expert manual invention. Automatic determination of the collection threshold on a per-sample basis removes the interference from drifting baselines or high background signals and increases ease of use. Fractions can be re-injected automatically if required, and information exported.


Scale from analytical UPLC to prep

Waters ultra-performance liquid chromatography (UPLC) technology has been widely accepted by chromatographers because of its improvements over high-performance liquid chromatography (HPLC) in sensitivity, resolution, and speed of separations. Now scientists can use this technology in the sample screening process as a tool to evaluate samples prior to purification as well as a tool for rapid analysis of fractions.

Scaling up from analytical UPLC to preparative HPLC is possible with the use of focused gradients. The efficiency of UPLC can be carried through to purification, offering a substantial increase in throughput and productivity. In a preparative environment, where the compound of interest is being isolated from the other components in the sample, retaining analytical resolution is not as important as isolating and collecting the single compound of interest.


Create the system that best fits your needs

Build a preparative LC system to match your needs, workload, and budget. Choose from a variety of components to configure a system that's right for your lab. Whether your application requires low- or high-pressure mixing, low or high flow rates, manual or automated injection and collection, you choose the level of functionality and capacity that your application requires. And since Waters Purification Systems are upgradable, you don't have to worry about your investment as your workload increases.

When fraction collection is based on UV absorbance, multiple fractions can result, requiring further analysis to determine the fraction of interest. Run samples around the clock with unprecedented versatility and consistency. Add the System Fluidics Organizer to easily manage column selection and column regeneration. FractionLynx Application Manager manages and automates your sample purification process.

Waters offers multiple detection choices, including mass detection:

  • Ultraviolet/visible (UV/Vis) absorbance
  • Evaporative light scattering (ELS)
  • Photodiode array
  • Mass spectrometry (MS)
  • Analog

Easily manage sample injection and fraction collection with options:

  • Manual injection
  • Automated injection
  • Automated fraction collection
  • Automated injection and fraction collection (3767 Sample Manager)

Choose a solvent delivery system that matches your sample's needs:

Sample Load

Column I.D.

Fluid Handling Unit

Maximum Flow Rate

mg – mg

3.9–7.8 mm

1525 Binary HPLC Pump

10 mL/min

mg – 10s mg

3.9–19 mm

1525 Binary HPLC Pump and EF Kit

22.5 mL/min

mg – 10s mg

3.9–50 mm

2535 Quaternary Gradient Module

50 mL/min

mg – g

4.6–50 mm

2545 Binary Gradient Module

150 mL/min

mg – g

4.6–50 mm

2545 Quaternary Gradient Module

150 mL/min

mg – 10s g

7.8–75 mm

2555 Quaternary Gradient Module

300 mL/min

Resources

Documents

Documents


Support

Support



Related

Achieve fast, efficient, lab-scale separations, and greater throughput with Waters Preparative HPLC Columns, which provide predictable performance and easily scale from analytical to prep.

Acquire, analyze, manage, and share your nominal and exact mass, MS and MS/MS data with MassLynx Software for Waters mass spectrometry (MS) systems.

Automates sample purification, including the control of fraction collection as well as sample, fraction and data tracking.

Protect your Waters LC or LC-MS system investment and ensure optimum productivity and compliance with the range of plans in FlexCHOICE Instrument Service Coverage.
Back To Top Back To Top