Standard & Certified Sample Vials

Standard & Certified Sample Vials

Maximize lab efficiency with fewer failed assays and lower instrument downtime

Maximize lab efficiency with fewer failed assays and lower instrument downtime

Reducing failed assays from unknown contaminant peaks and limiting instrument downtime from out of specification vials or septa is a priority for your lab. Waters sample vials, caps & septa can help you do just that.

Quality controlled via a multi-step certification process, we ensure that Waters Certified vials meet and maintain specified levels of cleanliness, glass surface properties, controlled pH shifts and adsorptive losses - from batch to batch and vial to vial. Choosing the right sample vial for small and large molecule HPLC or UHPLC applications for UV and MS can help meeting the business demand of your laboratory and the requirement of delivering the result with the best quality needed for your analysis.

Find the right vial
Vials combine neutral glass for low adsorption of small molecules with very few background masses detected by MS Standard & Certified Sample Vials

Specifications

Overview

  • Available in LC-GC, LC-MS, and TruView pH Control LCMS Certified Vials with cleanliness tested by UPLC-UV and MS
  • Consistent vial-to-vial and lot-to-lot performance
  • High recovery vials for limited sample volumes
  • Compatible with all autosamplers and designed to fit a range of caps
  • Complete selection of vial sizes and materials with combination packs for easy ordering
  • Reduced analyte peak variability for results you can rely on

Recommended Use: To reduce risk for your LC analysis while increasing consistency and reproducibility.


Which vial is right for your lab?

Which vial is right for your lab?

Glass and Polypropylene Vials
  • Application: Glass for basic and legacy methods. Polypropylene where glass is not applicable.
  • Benefit: Low cost, high value.
  • Certification test: Dimensional consistency
Waters Certified Vials
  • Application: Routine QC LC-UV analysis of compounds in µg/mL concentrations.
  • Benefit: No UV interference caused by manufacturing and packaging residues of glass and septum.
  • Certification test: UPLC-UV at 195 nm, dimensional consistency
Waters LCMS Certified Vials
  • Application: Routine QC and LC-MS analysis with lower analyte concentrations from 10-100s ng/mL.
  • Benefit: Low MS interference of known residues and polymers from glass and septum manufacturing.
  • Certification test: LC-MS cleanliness; LC-UV cleanliness; dimensional consistency
Waters TruView pH Controlled LCMS Certified Vials
  • Application: LC-MS and routine QC analysis and quantification for pH-sensitive compounds and unbuffered dilluents; reduced adsorption of polar bases with high vial-to-vial consistency
  • Benefit: Enhanced glass surface to reduce leaching of Na and other metal ions into solution with a high level of consistency; reduced adsorption effects. Lowest MS interference of residues and polymers from glass and septum manufacturing
  • Certification test: UPLC-UV at 195 nm, pH Control, MS Analyte adsorption and MS scan for cleanliness, dimensional consistency

Control data quality risks and reduce unexpected or ghost peaks

Don’t let the presence of background noise impact your results, causing data quality risks and unexpected or ghost peaks. Background noise can come from many factors. One of the most important factors are vial and septa cleanliness, which introduces contamination peaks. Ghost peaks are introduced by analyte degradation that can be triggered by significant pH changes in the diluent. In this chromatogram, the top shows normal behavior, and the bottom chromatogram shows ghost peaks.

Waters Certified vials are cleanliness tested so you don’t have to worry about contaminant peaks. The TruView pH Control Vials are certified to minimize and control a pH shift away from the neutral.


More time on development. Less on troubleshooting.

Stop losing valuable development time on troubleshooting due to analyte loss from non-specific adsorption. Waters TruView pH Control LCMS Certified Vials have the lowest adsorptive losses on the market, and you can rely on them to provide consistency from batch to batch and vial to vial. This chromatogram shows a comparison of adsorptive loss of chlorhexidine in a variety of vials.


Ideal for demanding MS work

LCMS Certified Vials are suited for analyte concentrations in the 100s ng/mL concentration. Waters LCMS Certified Vials are tested by MS scans from 250 to 1000 m/z with specifications set on the total ion count and presence of clusters in the high mass range. This chromatogram shows a comparison of typical MS scans of Waters LCMS Certified Vials to vials of other sources and clean solvents.


Resources

Documents

Documents



Related

Reduce sample losses due to non-specific binding (NSB) and ionic interactions with QuanRecovery Vials and Plates with MaxPeak High Performance Surfaces.

Browse 96- and 384-well plates that meet ANSI and SBS standards, offer various sealing options and fit numerous manifolds, autosamplers and robots.

Get reliable results with Waters Certified Containers, these solvent and mobile-phase bottles are ultra-clean and can be used on any LC system, including UPLC, LC/UV, and LC-MS, among others.

Leave no analyte behind with Waters TruView pH Control LCMS certified glass low adsorption autosampler vials - certified/tested for analyte recovery on a UPLC-MS/MS and certified for minimum pH shift away from the neutral.

Offers and Discounts

Back To Top Back To Top